Main performance parameters of coal water mixture boiler
Boiler type
Items
|
SZS2-1.25-J
|
SZS4-1.25-J
|
SZS6-1.25-J
|
SZS10-1.25-J
|
Rated output(t/h)
|
2
|
4
|
6
|
10
|
Rated working pressure(Mpa)
|
1.25
|
1.25
|
1.25
|
1.25
|
Rated steam temperature
|
Saturated
|
Saturated
|
Saturated
|
Saturated
|
Feedwater temperature
|
20
|
105
|
105
|
105
|
Combustion mode
|
Chain layer combustion
|
Chain layer combustion
|
Chain layer combustion
|
Chain layer combustion
|
Applicable fuel
|
Coal water mixture
|
Coal water mixture
|
Coal water mixture
|
Coal water mixture
|
Maximum size of transportation cargo(L x W x H)mm
|
6300x3100x3540
|
7100x3400x3540
|
8700x3800x3600
|
14850x7800x10450
|
Maximum weight of transportation cargo(t)
|
31.5
|
35.5
|
45
|
bulk
|
Boiler type
Items
|
YSL-700J
|
YSL-1050J
|
YSW-2800J
|
Thermal output(MW)
|
0.7(60)
|
1.05(90)
|
2.8(240)
|
Rated working pressure(Mpa)
|
0.7
|
0.7
|
1.0
|
The fuel consumption at full load operation(kg/h)
|
180
|
270
|
720
|
Rated working temperature
|
≤300
|
≤300
|
≤300
|
The circulation oil volume(m3)
|
51
|
76
|
163
|
Overall dimension(L x W x H)mm
|
2740x2350x3290
|
3250x2360x3590
|
6900x2720x3460
|
Total weight of equipments(t)
|
17.5
|
21.5
|
36
|
Boiler type
Items
|
YSW-4200-J
|
YSW-7000-J
|
YSW-14000-J
|
Thermal output(MW)
|
4.2(360)
|
7.0(600)
|
14.0(1200)
|
Rated working pressure(Mpa)
|
1.0
|
1.0
|
1.0
|
The fuel consumption at full load operation(kg/h)
|
1080
|
1800
|
3600
|
Heating area(m2)
|
271
|
350.3
|
735
|
Rated working temperature
|
≤300
|
≤325
|
≤325
|
The circulation oil volume(m3)
|
244
|
360
|
650
|
Overall dimension(L x W x H)mm
|
8350x2900x3460
|
9700x3300x6460
|
17300x8550x11000
|
Total weight of equipments(t)
|
48
|
87.5
|
177.5
|
Boiler type
Items
|
SHFS4-1.25-J
|
SHFS6-1.25-J
|
SHFS10-1.25-J
|
Rated output(t/h)
|
4
|
6
|
10
|
Rated working pressure(Mpa)
|
1.25
|
1.25
|
1.25
|
Steam temperature
|
Saturated
|
Saturated
|
Saturated
|
Rated feedwater temperature
|
20
|
105
|
105
|
Combustion mode
|
Fluidization suspension combustion
|
Fluidization suspension combustion
|
Fluidization suspension combustion
|
The circulation oil volume(m3)
|
244
|
360
|
650
|
Applicable fuel
|
Coal water mixture(CWM)
|
Coal water mixture(CWM)
|
Coal water mixture(CWM)
|
Maximum elevation of boiler proper(mm)
|
6000
|
6300
|
6700
|
Overall dimension of installation for boiler proper(L X W X H)mm
|
8300X6800X6000
|
8500X6800X6300
|
10670X7550X6700
|
Boiler type
Items
|
SHFS20-1.6-SM
|
SHFS35-3.82/450-SM
|
SHFS75-3.82/450-SM
|
Rated output(t/h)
|
20
|
35
|
75
|
Rated working pressure(Mpa)
|
1.6
|
3.82
|
3.82
|
Steam temperature
|
Saturated
|
450
|
450
|
Rated feedwater temperature
|
105
|
105
|
105
|
Combustion mode
|
Fluidization suspension combustion
|
Fluidization suspension combustion
|
Fluidization suspension combustion
|
The circulation oil volume(m3)
|
244
|
360
|
650
|
Applicable fuel
|
Coal water mixture(CWM)
|
Coal water mixture(CWM)
|
Coal water mixture(CWM)
|
Maximum elevation of boiler proper(mm)
|
8000
|
11100
|
14000
|
Overall dimension of installation for boiler proper(L X W X H)mm
|
12650x7950x8000
|
15280x7950x11100
|
18100x1050x14000
|
Boiler type
Items
|
SHFS2.8-1.0/115/70-J
|
SHFS4.2-1.0/115/70-J
|
SHFS7.0-1.0/115/70-J
|
Rated thermal power(MW)
|
2.8
|
4.2
|
7.0
|
Rated working pressure(Mpa)
|
1.0
|
1.0
|
1.0
|
Rated effluent temperature
|
115
|
115
|
115
|
Rated return water temperature
|
70
|
70
|
70
|
Combustion mode
|
Fluidization suspension combustion
|
Fluidization suspension combustion
|
Fluidization suspension combustion
|
Applicable fuel
|
Coal water mixture(CWM)
|
Coal water mixture(CWM)
|
Coal water mixture(CWM)
|
Maximum weight of transportation cargo(t)
|
6000
|
6300
|
6800
|
Overall dimension of installation for boiler proper(L X W X H)mm
|
8300X6800X6000
|
8500X6800X6300
|
15280X6950X6800
|
Boiler type
Items
|
SHFS14.0-1.0/115/70-J
|
SHFS29.0-1.0/115/70-J
|
Rated thermal power(MW)
|
14.0
|
29.0
|
Rated working pressure(Mpa)
|
1.0
|
1.0
|
Rated effluent temperature
|
115
|
115
|
Rated return water temperature
|
70
|
70
|
Combustion mode
|
Fluidization suspension combustion
|
Fluidization suspension combustion
|
Applicable fuel
|
Coal water mixture(CWM)
|
Coal water mixture(CWM)
|
Maximum weight of transportation cargo(t)
|
8000
|
11100
|
Overall dimension of installation for boiler proper(L X W X H)mm
|
12650x7850x8000
|